Thermal imaging camera comparison Flir c5 Vs Fluke Pti 120

Thermal imaging camera Comparison Flir c5 Vs Fluke Pti 120

Both Flir c5 and fluke pti120 are basic level pocket friendly thermal imaging camera to start with. we have compared both the thermal imaging camera. differences as bellow

compare-flirc5-and-fluke-pti-120

Price (No authorized vendor in our database. We still can help you to find correct vendor if you want ) taken from online portals 69985 @ amazon.in 85000 @ flipcart.com
IFOV (spatial resolution) 7.6 mRad 6.3mrad/pixel
Infrared resolution 120 x 90 (10,800pixels) 160 × 120 (19,200 pixels)
Field of view 50° H x 38° V 54° × 42°
Distance to spot 130:1 • Thermal: 0.1 m (3.94 in)
• MSX®: 0.3 m (11.8 in)
Temperature measurement range (not calibrated below -10 °C) -20 ° C to 150 ° C -20 to 400°C (-4 to 752°F)
Focus system Fixed focus, minimum focus distance 22.8 cm Fixed. • Thermal: 0.1 m (3.94 in)
• MSX®: 0.3 m (11.8 in)
USB Mini USB used to transfer image to PC USB 2.0, Type-C connector
Wifi Yes 802.11 a/ac/b/g/n (2.4 and 5 GHz)
Fluke Connect® Instant Upload Yes, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect® system or your local server for storage and viewing on your PC (802.11 bgn (2.4 GHz)) Directly upload images to FLIR Ignite cloud library and services
Image quality  
IR-Fusion technology Yes, adds the context of the visible details to your infrared image yes
AutoBlend mode Continuous 0% to 100% yes
Touchscreen display 3.5’’ (landscape), 320 x 240 LCD 3.5”
Rugged, ergonomic design Yes Yes
Thermal sensitivity (NETD) 60 mK <70 mK
Frame rate 9 Hz 8.7 Hz
Data storage and image capture      
Memory ≥ 2 GB internal flash memory 1.5 GB
Image capture, review, save mechanism One-handed image capture, review, and save capability yes
Image file formats Non-radiometric (jpeg), or fully radiometric (.is2); no analysis software required for non-radiometric (jpeg) files  
Software Fluke Connect® desktop software—full analysis and reporting software with access to the Fluke Connect system  
Export file formats with software JPG, IS2  
Measurement Range -20 °C~150 °C  
Battery      
Batteries (rechargable) Internal rechargeable lithium ion battery. Rechargeable built-in Lithium ion battery
Battery life ≥ 2 hours continuous (without WiFi) 4 hours
Battery charging time ≤ 1.5 hours 2 hours
Battery charging system Micro USB cord from product to PC USB-C (1 A)
AC operation With separate AC to USB adapter.
Not included in box
 
Power saving Automatic Shutdown:
5, 10, 15 and 20 minutes or never
 
Temperature measurement      
Temperature measurement range (not calibrated below -10 °C) -20 ° C to 150 ° C -10 to 50°C (14 to 122°F)
Accuracy Target temp at or over 0 °C: Accuracy: ± 2° C or ± 2 %  
On-screen emissivity correction Yes  
On-screen reflected background temperature compensation Yes  
Color palettes      
Standard palettes 6: Ironbow, Blue-Red, High Contrast, Amber, Hot Metal, Grayscale  
General specifications      
Color alarms (temperature alarms) High temperature, low temperature, and isotherms (within range)  
Infrared spectral band 8 μm to 14 μm (long wave)  
Operating Temperature -10 °C to +50 °C (14 °F to 122 °F)  
Storage Temperature -40 °C to +70 °C (-40 °F to 158 °F)  
Relative humidity 95 % non-condensing  
Center-point temperature Yes  
Spot temperature Hot and cold spot markers  
Safety EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN
60529, EN 62133 (lithium battery)
 
Electromagnetic compatibility EN301 489-1 V2.1.1 EN301489-17 V3.1.1  
US FCC CFR, Part 15C  
Vibration and shock 2G, IEC 68-2-6 and 25G, IEC 68-2-29  
Drop 1 meter Designed for 2 m (6.6 ft)
Size (H x W x L) 8.9cm x 12.7cm x 2.5cm (3.5 in x 5.0 in x 1.0 in) 138 × 84 × 24 mm (5.4 × 3.3 × 0.94 in)
Weight 0.233 kg (0.514 lb) 0.19 kg (0.42 lb)
Enclosure rating IP54 IP54 (IEC 60529)
Warranty Two-years 2 Yrs